Order No. MD0104075S1

J1

Portable Stereo CD System

Color

(A) ... Blue Type

(R) ... Red Type

(S) ... Silver Type

P ... U.S.A.

Tape Deck: SG20 Mechanism Series

Traverse Deck: RAE0152Z-1C Mechanism Series

Subject: Change the Version (A6) to (J1) (Correction)

Please delete the RX-D13(P) (A6) version ( Order No. MD0102028C1) and use this supplement manual (J1) version.

 RADIO

Frequency Range

FM
87.9-107.9 MHz (200 kHz steps)

87.5-108.0 MHz (100 kHz steps)
AM
520-1710 kHz (10 kHz steps)
Intermediate Frequency

AM
450 kHz
FM
10.7 MHz
Sensitivity

AM
46 dB/m/50 mW
FM
15 dB/50 mW


 TAPE RECORDER

Track System
4 track, 2 channel, stereo
Monitor system
Variable sound monitor
Recording system
AC bias
Erasing system
Multi pole magnet
Frequency range

Normal position
50 ~ 12000 Hz


 CD PLAYER

Sampling frequency
44.1 kHz
Decoding
16 bit linear
Beam source
Semiconductor laser (wavelength 780 nm)
No. of channels
2 channel, stereo
Wow and flutter
Less than possible measurement data
D/A converter
(1 bit DAC)


 GENERAL

Power Requirement

AC
120 V, 60 Hz

Power Consumption : 14 W
Battery
9 V (six R20/LR20, D, UM-1 batteries)
• Do not use rechargeable type batteries.
Memory back-up
6 V (four R6/LR6, AA, UM-3 batteries)
• Do not use rechargeable type batteries.
Speakers
10 cm (3-15/16”) 4Ω x 2
Jacks

Output
Phones : 3.5 mm stereo (32Ω)
Dimensions (W x H x D)
420 x 167 x 275 mm

(16-17/32” x 6-31/32” x 10-13/16”)
Mass
3.4 kg (7 lb. 8 oz.) without batteries
Power consumption in standby mode : 1 W


Notes:
  1. Specifications are subject to change without notice.
  2. Mass and dimensions are approximate.

© 2001 Matsushita Electronics (S) Pte. Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law.

Location of Controls

Battery Service Life

UM-1 (D-size) Batteries/Approximately 30 hrs of Tape Recording. (EIAJ)/Approximately 16 hrs of Tape Playback. (EIAJ)/Approximately 11.5 hrs of CD Recording. (EIAJ)/Approximately 10.5 hrs of CD Playback. (EIAJ)

The battery service life is measured according to the conditions set forth by EIAJ. (Electronic Industries Association of Japan). As the battery service life varies with the method of operation and environmental conditions, use these values as reference.

Schematic Diagram Note

(All schematic diagrams may be modified at any time with the development of new technology.)

Notes:

S702
Open Switch
S703
Rest Switch
SW302
Function Switch
SW601
Auto Scan Switch
SW602
XBS/TONE/HES Switch
SW603
Play Mode Switch
SW604
Memory Switch
SW605
REV Skip Switch
SW606
FWD Skip Switch
SW607
Play/Pause Switch
SW608
CD Stop Switch
SW1001
Record Switch
SW1002
Leaf Switch
VR301
Volume VR

Battery Current:

Volume minimum :

119 mA (FM)

112 mA (AM)

187 mA (TAPE Playback)

169 mA (CD REC)

Volume maximum :

119 mA (FM)

112 mA (AM)

187 mA (FM RADIO REC)

181 mA (AM RADIO REC)

187 mA (TAPE Playback)

238 mA (CD REC)

  • The voltage value and waveforms are the reference voltage of this unit measured by DC electronic voltmeter (high impedance) and oscilloscope on the basis of chassis. Accordingly, there may arise some error in voltage values and waveformsdepending upon the internal impedance of the tester or the measuring unit.

    No mark
    ...Playback
    < >
    ...FM
    (( ))
    ...CD
    ( )
    ...AM

  • Importance safety notice:

    Components identifed by mark have special characteristics important for safety. Furthermore, special parts which have purposes of fire-retardant (resistors), high-quality sound (capacitors), low-noise (resistors), etc. are used. Whenreplacing any of components, be sure to use only manufacturer’s specified parts shown in the parts list.

Caution!

IC, LSI and VLSI are sensitive to static electricity.

Secondary trouble can be prevented by taking care during repair.

  • Cover the parts boxes made of plastics with aluminium foil.

  • Put a conductive mat on the work table.

  • Ground the soldering iron.

  • Do not touch the pins of IC, LSI or VLSI with fingers directly.

Schematic Diagram

Replacement Parts List

Notes:

  • The parenthesized indications in the Remarks column specify the areas or color. (Refer to the cover page for area or color.)

    Parts without these indications can be used for all areas.

  • [M] indicates in the Remarks columns indicates parts that are supplied by MESA .

  • The “(SF)” mark denotes the standard part.

  • Remote Control Unit: Supply period for three years from terminal of production.

  • Reference for O/I book languages are as follows :

    Ar : Arabic
    Cf : Canadian French
    Cz : Czech
    Da : Danish
    Du : Dutch
    En : English
    Fr : French
    Ge : German
    It : Italian
    Ko : Korean
    Po : Polish
    Ru : Russian
    Sp : Spanish
    Sw : Swedish
    Co : Traditional Chinese
    Cn : Simplified Chinese

Accessories Parts List
Ref. No.
Part No.
Part Name & Description
Remarks


ACCESSORIES





A1
EUR648257
REMOTE CONTROLLER
[M]
A1-1
UR64EC2337A
R/CA BATTERY COVER
[M]
A2
RJA0065-1D
AC CORD
[M]
A3
RQT5685-1P
O/I BOOK (En)
[M]

AC power cord.... 1 pc

Remote Control.... 1 pc

/Printed in Singapore/M010400001FLE/E

@