HDD/SSD

This section allows you to monitor and understand the status of internal storage drives installed on your Synology NAS. Go to Storage Manager > HDD/SSD to manage these options.

To check the HDD/SSD info:

  1. Go to the HDD/SSD tab.
  2. Select a drive from the list and expand it. Here you will see the health status, storage pool info, model name, serial number, firmware version, temperature, and other information.

Note:

To check the health info:

  1. Go to the HDD/SSD tab.
  2. Select a drive.
  3. Click Health Info.
  4. Go to the Overview tab to find out how many hours the drive has been powered on, and to view its current temperature, reconnection/re-identification count, and bad sector count.
  5. Go to the S.M.A.R.T. tab to perform diagnostic tests on the supported drive and view the S.M.A.R.T. attributes. In the S.M.A.R.T. Test section, you can run an S.M.A.R.T. test immediately and view the test results and schedule; in the S.M.A.R.T. Attribute section, you can view the details of the S.M.A.R.T. attribute values.
  6. Go to the IronWolf Health tab to perform diagnostic tests on the supported drive.
  7. Go to the History tab to view and export the health diagnosis results and to view the history of the major S.M.A.R.T. attributes.
Drive Status Health Condition
Normal The drive is either in a good condition, or the warning about the drive has been suppressed or disabled.
Warning Issues have been detected on the drive and/or bad sector count has exceeded the set limit. Even though drives in this status may still be serviceable, they should be monitored.
Critical A critical issue or multiple issues have been detected on the drive. Replacing the drive immediately is highly recommended.
Failing Multiple critical issues have been detected on the drive. Drive integrity is not guaranteed when drives are in this health status.
Access Error Drive communication errors may have caused the drive to disconnect from the system or have resulted in severe read-write failure. This health status usually indicates that severe issues have occurred.

Note:

To modify the drive warning status:

DSM constantly monitors the health status of your drives, and will alert you when issues are detected. Some issues may be more serious than others. For certain issues resulting in Warning health status (at Health Info > Overview), the warning can be modified by doing the following:

  1. Go to the HDD/SSD tab.
  2. Select the drive in warning status and click Health Info.
  3. Click Modify Drive Warning.
  4. Click on the Suppress Warning or Disable Warning option (you may be presented with these two options, depending on the type of issue):

Note:

To start the S.M.A.R.T. test**:

The S.M.A.R.T. Test section will examine and report the status of your drives, alerting you of possible drives failures. We recommended promptly changing your drives if the test fails.

  1. Go to the HDD/SSD tab.
  2. Select a drive.
  3. Click Health Info.
  4. Go to the S.M.A.R.T. tab.
  5. Choose a test type and click Start to begin the test.
  6. The latest test results are displayed in the Test Result section.
  7. Go to the History tab to view previous test results.

Note:

To schedule S.M.A.R.T. tests**:

S.M.A.R.T. tests can be scheduled to run automatically on drives.

  1. Go to the Test Scheduler tab.
  2. Click Create to set up a new task.
  3. Modify the following settings on the General tab:
  4. On the Schedule tab, modify the following settings:
  5. Click OK to finish.

Note:

To start the IronWolf Health test:

Seagate IronWolf Health Management relies on additional drive telemetry data, which contains more information than S.M.A.R.T.. We recommend you to follow the suggestions shown in each test result status.

  1. Go to the HDD/SSD tab.
  2. Select a drive.
  3. Click Health Info.
  4. Go to the IronWolf Health tab.
  5. Click Start to begin the test. The Test Result section shows the latest test results.
  6. Go to the History tab to view previous test results.

Please see the table below for an overview of the output codes from the IronWolf Health test.

Output Codes from IronWolf Health Management Definition
100 Abnormally high operating temperature has been detected. Please make sure that the rear ventilation ports are not blocked, and please try to lower the ambient temperature. If the temperature is still high, please go to Control Panel > Hardware & Power > Fan Speed Mode to change the fan operation to a higher speed. If this issue persists, please contact Synology Support Team.
101 Connection issue on your DiskStation and hard drive interface has been detected. Please make sure that the drive is properly installed in the chassis or drive tray, and that the tray is properly installed in your DiskStation. If this issue persists, please contact Synology Support Team.
102 Excessive physical shock to the drive has been detected. Please make sure your hard drive and DiskStation are placed on a stable surface. If this issue persists, please contact Synology Support Team.
105 Excessive vibration has been detected. Please make sure your DiskStation is placed on a stable surface. If this issue persists, please contact Synology Support Team.
106 Excessive host resets have been detected. Please make sure the drive is properly installed in the chassis or drive tray. We recommend you to perform a power cycle. If this issue persists, please contact Synology Support Team.
200, 201, 202 and 203 To check the health status of your drive, it is recommended to run the S.M.A.R.T. extended test on the drive. If this issue persists, please contact the drive reseller or manufacturer.

Note:

To schedule IronWolf Health tests*:

IronWolf Health tests can be scheduled to automatically run on drives.

  1. Go to the Test Scheduler tab.
  2. Click Create to set up a new task.
  3. Go to the General tab to modify the following settings:
  4. Go to the Schedule tab to modify the following settings:
  5. Click OK to finish.

Note:

To enable bad sector warning support*:

  1. Go to the Settings tab.
  2. Tick Enable bad sector warning. By default, this function is enabled.
  3. Click Apply.

To enable SSD lifespan warning support*:

  1. Go to the Settings tab.
  2. Tick Enable SSD lifespan warning. By default, this function is enabled.
  3. Set the limit in the Lifespan percentage (%) field. The status of an SSD will be changed to Warning when the estimated lifespan is below the value specified here.
  4. Click Apply.

Note:

To perform Benchmark*:

  1. Go to the HDD/SSD tab.
  2. Select a drive and click Benchmark.
  3. In the window that appears, click Run Test Now to start the performance test. Results will be displayed here when the test is finished.
  4. To compare the result with previous tests, click Select in the Compared test field to choose the desired log.

Note:

To perform Secure Erase:

  1. Go to the HDD/SSD tab.
  2. Select a drive and click Action > Secure Erase.

Note:

To deactivate a drive:

  1. Go to the HDD/SSD tab.
  2. Select a drive and click Action > Deactivate.

Note:

To switch the status of LED drive indicators:

  1. Go to the HDD/SSD tab.
  2. Select a drive and click Action > Switch Drive Indicator Status.
  3. Select the amount of time the drive indicator remains "alert" for.
  4. Click Switch to switch drive indicator status.
  5. To restore drive indicator status, click Restore.

Note:

To update S.M.A.R.T. Database:

S.M.A.R.T. Database contains information related to the safe operating temperature and S.M.A.R.T. field names of a drive. The database is updated periodically and is updated automatically after a drive is replaced. This operation should be executed only when periodic or automatic database update fails.

  1. Go to the Settings tab.
  2. Scroll down to the S.M.A.R.T. Database section.
  3. Click Update Now.

Note:

Enabling the Write Cache Support for HDD

Enabling the write cache support optimizes the system performance of your DiskStation. Only certain HDD models support this feature. To ensure data protection while using write cache support, usage of a UPS device is strongly recommended. We also suggest you to shut down the system properly every time after use. Disabling the write cache will reduce the chances of data loss caused by abnormal power outages.

To enable write cache support:

  1. Go to the HDD/SSD tab.
  2. Select a drive and click Action > Configure.
  3. Tick Enable write cache and click Apply. By default, this function is enabled.

____
* Available on certain models only.
** NVMe SSDs have a built-in monitoring mechanism and therefore will not support S.M.A.R.T. test or bad sector warning.